| Productinfo | Hardware specs | XR Hardware specs |
The IviumStat is available in two versions:
|
|
and |
|
Key features:
• Wide application range:
The instrument is well suited for applications requiring a wide dynamic range, such as Battery-testing, Corrosion-measurements and Electrochemical Research applications.
• Complete solution:
The IviumStat offers a complete package. The hardware includes a build-in high-performance Frequency Response Analyser, and all the standard Electrochemical techniques. All measurement and dataprocessing software is included (for Windows based pc’s).
• Safety:
The compliance (maximum current or potential) of the instrument can be defined by the operator. Thus valuable samples may be protected, and unsafe situations prevented.
• Automation:
Multiple analog and digital input & output ports are available, that can monitor & control peripheral equipment. The included software integrates this functionality.
• Multiple Channel option:
Up to 64 IviumStats may be controlled with a single PC via USB.
• Expandibility:
optional Bipotentiostat-, True Linear Scan- and Coulometer-modules are available.
Techniques:
• General:
- Automatic current range selection: 1pA to 10A, and voltage range 1mV to 10V (20V).
- Automatic variable noise filter and potentiostat/galvanostat stability settings
- Simultaneous acquisition of current/potential and up to 8 peripheral analog signals
- Real time data display up to 500 pnts/s. Acquisition up to 100,000 pnts/s is stored in instrument memory.
• Sweep methods: Linear Sweep and Cyclic Voltammetry:
- Applicable scanrates: 1µV/s to 10,000 V/s
- Standard scanrange ± 10V, with 0.3mV step resolution.
- High definition scanrange ± 100mV, with 3µV step resolution.
• Pulse methods: multiple potentiostatic/galvanostatic pulses
- Up to 255 potential or current levels may be defined
- Minimum pulse duration 50µs, definable with 0.125µs resolution.
- Minimum sampling interval: 10µs
• Electrochemical Impedance Spectroscopy
- Up to 255 frequencies may be applied during a single scan in the 10µHz to 2MHz range.
- Result optimalisation by automated tuned filters, gain amplifiers and dc-subtraction.
• Transient methods: Chronoamperometry&chronopotentiometry, ElectroChemical Noise
- Up to 255 potential or current levels may be defined
- Minimum pulse duration 50µs, definable with 0.125µs resolution.
- Minimum interval time: 10µs
- Mixed mode allows sequencing with definable electrical modes:
- Potential Step
- Current Step
- Potential Sweep
- Current Sweep
- Open Cell
- Real-time Impedance Measurements 10Hz-2MHz
- Minimum sample interval: 0.002 sec. and max. 2E9 datapoints/level
- Dynamic termination of stages: E>, E<, dE/dt<, dE/dT>, An1>, An1<, dAn1/dt<, Ifraction<, |Q|<, etc.
- ECN: Electrochemical Noise
- Build-in module, no extra hardware required
- Potential and current recorded simultaneously up to 500 pnts/sec
- Traces up to 2E9 pnts may be recorded